Package | ihe.iti.pcf |
Type | CapabilityStatement |
Id | Id |
FHIR Version | R4 |
Source | https://profiles.ihe.net/ITI/PCF/https://build.fhir.org/ig/IHE/ITI.PCF/CapabilityStatement-IHE.PCF.consentRecorder.html |
Url | https://profiles.ihe.net/ITI/PCF/CapabilityStatement/IHE.PCF.consentRecorder |
Version | 1.1.1-current |
Status | active |
Date | 2023-02-14 |
Name | IHE_PCF_consentRecorder |
Title | IHE PCF Consent Recorder |
Experimental | False |
Realm | uv |
Authority | ihe |
Description | CapabilityStatement for the Consent Recorder Actor Explain - uses [Access Consent \[ITI-108\]](ITI-108.html) to record new or updated Consent Resources |
Kind | requirements |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: CapabilityStatement IHE.PCF.consentRecorder
application/fhir+xml
, application/fhir+json
Note to Implementers: FHIR Capabilities
Any FHIR capability may be 'allowed' by the system unless explicitly marked as 'SHALL NOT'. A few items are marked as MAY in the Implementation Guide to highlight their potential relevance to the use case.
client
PCF Consent Recorder provides capability to record a Privacy Consent.
Recommend ATNA, encouraged IHE-IUA or SMART-app-launch
search-system
interaction.The summary table lists the resources that are part of this configuration, and for each resource it lists:
_include
_revinclude
Resource Type | Profile | R | S | U | C | D | Searches | _include | _revinclude | Operations |
---|---|---|---|---|---|---|---|---|---|---|
Consent | y | y | y | y | y | _lastUpdated, _id, status, patient |
create
, read
, update
, delete
, search-type
.PCF transaction Access Consent [ITI-108]
Conformance | Parameter | Type | Documentation |
---|---|---|---|
SHALL | _lastUpdated | date | When the resource version last changed |
SHALL | _id | token | Logical id of this artifact |
SHALL | status | token | Whether the Consent record is active |
SHALL | patient | reference | The Patient |
{
"resourceType" : "CapabilityStatement",
"id" : "IHE.PCF.consentRecorder",
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: CapabilityStatement IHE.PCF.consentRecorder</b></p><a name=\"IHE.PCF.consentRecorder\"> </a><a name=\"hcIHE.PCF.consentRecorder\"> </a><a name=\"IHE.PCF.consentRecorder-en-US\"> </a><h2 id=\"title\">IHE PCF Consent Recorder</h2><ul><li>Implementation Guide Version: 1.1.1-current </li><li>FHIR Version: 4.0.1 </li><li>Supported Formats: <code>application/fhir+xml</code>, <code>application/fhir+json</code></li><li>Supported Patch Formats: </li><li>Published on: 2023-02-14 </li><li>Published by: IHE IT Infrastructure Technical Committee </li></ul><blockquote class=\"impl-note\"><p><strong>Note to Implementers: FHIR Capabilities</strong></p><p>Any FHIR capability may be 'allowed' by the system unless explicitly marked as 'SHALL NOT'. A few items are marked as MAY in the Implementation Guide to highlight their potential relevance to the use case.</p></blockquote><h2 id=\"rest\">FHIR RESTful Capabilities</h2><div class=\"panel panel-default\"><div class=\"panel-heading\"><h3 id=\"mode1\" class=\"panel-title\">Mode: <code>client</code></h3></div><div class=\"panel-body\"><div><p>PCF Consent Recorder provides capability to record a Privacy Consent.</p>\n</div><div class=\"lead\"><em>Security</em></div><blockquote><div><p>Recommend <a href=\"https://profiles.ihe.net/ITI/TF/Volume1/ch-9.html\">ATNA</a>, encouraged <a href=\"https://profiles.ihe.net/ITI/IUA/index.html\">IHE-IUA</a> or <a href=\"http://www.hl7.org/fhir/smart-app-launch/\">SMART-app-launch</a></p>\n</div></blockquote><div class=\"lead\"><em>Summary of System-wide Interactions</em></div><ul><li>Supports the <code>search-system</code>interaction.</li></ul></div></div><h3 id=\"resourcesCap1\">Capabilities by Resource/Profile</h3><h4 id=\"resourcesSummary1\">Summary</h4><p>The summary table lists the resources that are part of this configuration, and for each resource it lists:</p><ul><li>The relevant profiles (if any)</li><li>The interactions supported by each resource (<b><span class=\"bg-info\">R</span></b>ead, <b><span class=\"bg-info\">S</span></b>earch, <b><span class=\"bg-info\">U</span></b>pdate, and <b><span class=\"bg-info\">C</span></b>reate, are always shown, while <b><span class=\"bg-info\">VR</span></b>ead, <b><span class=\"bg-info\">P</span></b>atch, <b><span class=\"bg-info\">D</span></b>elete, <b><span class=\"bg-info\">H</span></b>istory on <b><span class=\"bg-info\">I</span></b>nstance, or <b><span class=\"bg-info\">H</span></b>istory on <b><span class=\"bg-info\">T</span></b>ype are only present if at least one of the resources has support for them.</li><li><span>The required, recommended, and some optional search parameters (if any). </span></li><li>The linked resources enabled for <code>_include</code></li><li>The other resources enabled for <code>_revinclude</code></li><li>The operations on the resource (if any)</li></ul><div class=\"table-responsive\"><table class=\"table table-condensed table-hover\"><thead><tr><th><b>Resource Type</b></th><th><b>Profile</b></th><th class=\"text-center\"><b title=\"GET a resource (read interaction)\">R</b></th><th class=\"text-center\"><b title=\"GET all set of resources of the type (search interaction)\">S</b></th><th class=\"text-center\"><b title=\"PUT a new resource version (update interaction)\">U</b></th><th class=\"text-center\"><b title=\"POST a new resource (create interaction)\">C</b></th><th class=\"text-center\"><b title=\"DELETE a resource (delete interaction)\">D</b></th><th><b title=\"Required and recommended search parameters\">Searches</b></th><th><code><b>_include</b></code></th><th><code><b>_revinclude</b></code></th><th><b>Operations</b></th></tr></thead><tbody><tr><td><a href=\"#Consent1-1\">Consent</a></td><td>�</td><td class=\"text-center\">y</td><td class=\"text-center\">y</td><td class=\"text-center\">y</td><td class=\"text-center\">y</td><td class=\"text-center\">y</td><td>_lastUpdated, _id, status, patient</td><td/><td/><td/></tr></tbody></table></div><hr/><div class=\"panel panel-default\"><div class=\"panel-heading\"><h4 id=\"Consent1-1\" class=\"panel-title\"><span style=\"float: right;\">Resource Conformance: supported </span>Consent</h4></div><div class=\"panel-body\"><div class=\"container\"><div class=\"row\"><div class=\"col-lg-4\"><span class=\"lead\">Core FHIR Resource</span><br/><a href=\"http://hl7.org/fhir/R4/consent.html\">Consent</a></div><div class=\"col-lg-4\"><span class=\"lead\">Reference Policy</span><br/></div><div class=\"col-lg-4\"><span class=\"lead\">Interaction summary</span><br/><ul><li>Supports <code>create</code>, <code>read</code>, <code>update</code>, <code>delete</code>, <code>search-type</code>.</li></ul></div></div><p/><p/><div class=\"row\"><div class=\"col-12\"><span class=\"lead\">Documentation</span><blockquote><div><p>PCF transaction <a href=\"ITI-108.html\">Access Consent [ITI-108]</a></p>\n</div></blockquote></div></div><div class=\"row\"><div class=\"col-lg-7\"><span class=\"lead\">Search Parameters</span><table class=\"table table-condensed table-hover\"><thead><tr><th>Conformance</th><th>Parameter</th><th>Type</th><th>Documentation</th></tr></thead><tbody><tr><td><b>SHALL</b></td><td>_lastUpdated</td><td><code>date</code></td><td><div><p>When the resource version last changed</p>\n</div></td></tr><tr><td><b>SHALL</b></td><td>_id</td><td><code>token</code></td><td><div><p>Logical id of this artifact</p>\n</div></td></tr><tr><td><b>SHALL</b></td><td>status</td><td><code>token</code></td><td><div><p>Whether the Consent record is active</p>\n</div></td></tr><tr><td><b>SHALL</b></td><td>patient</td><td><code>reference</code></td><td><div><p>The Patient</p>\n</div></td></tr></tbody></table></div><div class=\"col-lg-5\">�</div></div></div></div></div></div>"
},
"url" : "https://profiles.ihe.net/ITI/PCF/CapabilityStatement/IHE.PCF.consentRecorder",
"version" : "1.1.1-current",
"name" : "IHE_PCF_consentRecorder",
"title" : "IHE PCF Consent Recorder",
"status" : "active",
"experimental" : false,
"date" : "2023-02-14",
"publisher" : "IHE IT Infrastructure Technical Committee",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "https://www.ihe.net/ihe_domains/it_infrastructure/"
}
]
},
{
"telecom" : [
{
"system" : "email",
"value" : "iti@ihe.net"
}
]
},
{
"name" : "IHE IT Infrastructure Technical Committee",
"telecom" : [
{
"system" : "email",
"value" : "iti@ihe.net"
}
]
}
],
"description" : "CapabilityStatement for the Consent Recorder Actor \n\nExplain\n- uses [Access Consent \\[ITI-108\\]](ITI-108.html) to record new or updated Consent Resources",
"jurisdiction" : [
{
"coding" : [
{
"system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code" : "001"
}
]
}
],
"kind" : "requirements",
"fhirVersion" : "4.0.1",
"format" : [
"application/fhir+xml",
"application/fhir+json"
],
"rest" : [
{
"mode" : "client",
"documentation" : "PCF Consent Recorder provides capability to record a Privacy Consent.",
"security" : {
"description" : "Recommend [ATNA](https://profiles.ihe.net/ITI/TF/Volume1/ch-9.html), encouraged [IHE-IUA](https://profiles.ihe.net/ITI/IUA/index.html) or [SMART-app-launch](http://www.hl7.org/fhir/smart-app-launch/)"
},
"resource" : [
{
"type" : "Consent",
"documentation" : "PCF transaction [Access Consent \\[ITI-108\\]](ITI-108.html)",
"interaction" : [
{
"code" : "create"
},
{
"code" : "read"
},
{
"code" : "update"
},
{
"code" : "delete"
},
{
"code" : "search-type"
}
],
"searchParam" : [
{
"name" : "_lastUpdated",
"type" : "date",
"documentation" : "When the resource version last changed"
},
{
"name" : "_id",
"type" : "token",
"documentation" : "Logical id of this artifact"
},
{
"name" : "status",
"type" : "token",
"documentation" : "Whether the Consent record is active"
},
{
"name" : "patient",
"type" : "reference",
"documentation" : "The Patient"
}
]
}
],
"interaction" : [
{
"code" : "search-system"
}
]
}
]
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.